Degraded disk performance on p6 520 running IBM i or Where’s my SAS raid auxiliary cache card?




Home » Tech Notes » Blog article: Degraded disk performance on p6 520 running IBM i or Where’s my SAS raid auxiliary cache card?

Degraded disk performance on p6 520 running IBM i or Where’s my SAS raid auxiliary cache card?

Here’s a fun one. When you install a new power6 520 with multiple partitions you might want one of them to own the internal SAS raid controller. If you planned to use Raid5 then you purchased the auxiliary cache card. Now when you add the SAS controller to the partition profile, you would think that it would take the cache card along with it since: 1) you aren’t given a option to select the cache card and 2) where the heck else should it go?

 Well you would be wrong. When you get the system up and running, you may notice that the drives are running in DEGRADED mode. This means that the system doesn’t see the aux cache card and to protect you from a SAS controller failure, it is kindly running without using any disk controller cache. Did I mention that it probably took you a LONG time to get to this point?

 Solution: Take a look at the server properties and you will notice that you have the SAS controller in T9 allocated but there is also a “SCSI Bus Controller” in C9 not being used. The C9 component is actually the aux cache card for the SAS Raid controller. Use Dynamic Logical Partitioning to add the C9 physical adapter to your partition and all will be well.

Share and Enjoy:
  • Digg
  • del.icio.us
  • Facebook
  • LinkedIn
  • StumbleUpon
  • Reddit


Leave a Reply

We're here to help!

1.800.991.9ASG (1.800.991.9274)

South Orange County:
(949) 777-0400

North Orange County:
(714) 919-7145

Los Angeles:
(213) 355-5899

North Los Angeles:
(818) 488-8198

Fax:
(949) 777-0401



IT solutions, IT systems integration and Green IT implementation and consulting by thinkASG.

©2010 thinkASG. All Rights Reserved. Terms Privacy Statement Site Map IBM Cisco VMWare Vision Solutions